Reolink RLC-410W IP Camera OS Command Injection Vulnerability
CVE-2021-40407 · Reolink RLC-410W IP Camera · Published 2022-01-28
How bad would it be?
7.2 out of 10
CVSS rates it high.
How likely is it to be used?
48%
Estimated chance of exploitation in the next 30 days, higher than 98% of all scored flaws (EPSS, 2026-10-29).
Is it already being used?
Yes
CISA has seen it exploited in real attacks. For US government agencies the fix is deadline passed 660 days ago (2025-01-08).
What CISA says to do
The impacted product could be end-of-life (EoL) and/or end-of-service (EoS). Users should discontinue product utilization if a current mitigation is unavailable.
Reolink RLC-410W IP cameras contain an authenticated OS command injection vulnerability in the device network settings functionality.
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection. An attacker can send an HTTP request to trigger this vulnerability.
Understand the kind of weakness behind this flaw. These resources teach the weakness, rather than reproduce this specific CVE. Follow the vendor's advice above to fix the affected product.
OS command injection
Input changes a command that the server runs through its operating system.
CWE is a catalogue of weakness types. Labels come from the sources shown and can differ or change. Resource matches reviewed 16 October 2026.
On SentryFeed
No story in the last 14 days has mentioned it.
Exploited flaws from CISA's KEV catalogue. Chance of exploitation from EPSS by FIRST. Descriptions and scores from the NVD. This product uses the NVD API but is not endorsed or certified by the NVD.